banner

Floor Heating Systems Installation North Olmsted OH

This page provides relevant content and local businesses that can help with your search for information on Floor Heating Systems Installation. You will find informative articles about Floor Heating Systems Installation, including "Electric Radiant Floors". Below you will also find local businesses that may provide the products or services you are looking for. Please scroll down to find the local resources in North Olmsted, OH that can help answer your questions about Floor Heating Systems Installation.

Conway Heating & Air Cond
(440) 333-3500
20500 Lorain Rd
Fairview Park , OH
 
Conserv Air Htg & Air Cond
(216) 889-8800
4181 Rocky River Dr
Cleveland , OH
 
Climate Tech Inc
(440) 327-1833
7900 Root Rd Suite A
North Ridgeville , OH
 
Solitaire Htg & Cooling Inc
(614) 875-5740
1998 Harrisburg Pike
GroveCi, OH
 
JD Indoor Comfort Inc
(440) 949-8758
4040 Colorado Ave
Sheffield Lake , OH
 
Design Air Heating & Cooling LLC
(216) 214-0945
15874 Agnes Blvd
Brook Park , OH
 
Stack Heating & Cooling
(440) 937-9134
1431 Lear Industrial
Avon , OH
 
Slife Heating & Cooling Inc
(216) 221-0310
13729 Madison Ave
Lakewood , OH
 
Lorain County Htg A/C & Plbg
(440) 322-3500
633 W Broad St
Elyria , OH
 
Luxury Heating Co
(440) 366-0971
5327 Ford Rd
Elyria , OH
 

Electric Radiant Floors

You want to look for a product that can be installed in a single layer of thinset cement rather than two layers. This is faster and easier. You also want to find a product where the fiberglass (or other supporting material) forms an umbrella protection over the resistance wire so that your trowel can glide over the fiberglass net without risk of nicking the wire. Some products weave their wire over-and-under a fiberglass net. In that case the resistance wire will always appear on the surface and you face a greater risk of nicking the cable with your trowel ·Thickness of the cold-lead wires that connect the heating rolls to the thermostat: You want the thinnest cold-lead wires available (1/8" thick), so you can easily cover them with thinset cement like the heat resistance wire. If the cold-lead wires are thicker you will need to chisel a grove in the cement slab, or use a circular saw to cut a groove in the plywood sub-floor or backer board to maintain the floor level flat.

· Length of the cold-lead wires: You want cold lead wires that are long enough to connect to the thermostat without additional cut-&-turns of the roll to bring the roll closer to the thermostat.

·Vendor Technical Support Look for a vendor who will design an installation layout customized to your own floor plan. Understand that the heat will not extend very much laterally through conduction. In most cases the heat will extend 1.5" away from the wires but not more.

Therefore it is import...

Click here to read the rest of this article from Handyman