banner

Steam Heaters Avondale AZ

This page provides useful content and local businesses that can help with your search for Steam Heaters. You will find helpful, informative articles about Steam Heaters, including "Steam Heat Basics". You will also find local businesses that provide the products or services that you are looking for. Please scroll down to find the local resources in Avondale, AZ that will answer all of your questions about Steam Heaters.

Bob Brown Air Conditioning
(623) 979-8422
10020 W Santa Fe Dr
Sun City , AZ
 
Deer Valley Mechanical LLC
(623) 362-0361
21509 N 78th Ave Suite 140
Peoria , AZ
 
Parker & Sons
(480) 963-1829
3636 E Anne St Suite A
Phoenix , AZ
 
Premier Air Conditioning & Htg LLC
(623) 826-3398
15828 W Duane Ln
Surprise , AZ
 
Arizona Refrigeration Service
(480) 968-2898
1009 W Broadway Rd Suite C
Tempe , AZ
 
Hobaica Refrigeration Co Inc
(602) 995-0387
7027 N 27th Ave
Phoenix , AZ
 
Hackney Refrigeration
(480) 940-9814
4025 E Chandler Blvd #70-C22
Phoenix , AZ
 
Dial One Mears Air Cond & Htg Inc
(602) 997-5701
743 East Dunlap Avenue
Phoenix , AZ
 
Goettls High Desert Mechanical
(928) 567-2200
4650 Old Hwy 279 Unit A
Camp Verde , AZ
 
Arizona Comfort Systems Htg & Clg
(520) 459-5681
131 S Schrader Rd
Sierra Vista , AZ
 

Steam Heat Basics

Operating Pressure

The setting on your boiler for cut in and cut out is controlled by the pressuretrol. The pressure it cuts in at should be set at 1/2 pound (.5 psi) and the pressure it cuts out at should be 1 pound higher at 1 1/2 pounds (1.5 psi). This should be enough pressure to move the steam in your house. If you don't know how to adjust this, have it adjusted by your service tech next time your boiler is tuned up.

If you find that the pressure is adjusted DOWN significantly from where it was to get the .5 to 1.5 operating range, monitor your system's operation. If some radiators are not getting hot, check and replace the main line air vents. The system's pressure may have been raised (erroneously) to compensate for nonworking air vents.

Low pressure is safe. Overpressure is NOT safe.

Low water cutoff

Be sure your boiler has a functioning low water cutoff. Steam systems lose a little bit of water all the time, so there has to be water makeup. Some units have an auto feed, some are done manually. In either case, you want to be sure, the unit will shut off if there is low water. Firing an empty boiler will destroy the boiler and perhaps worse... Check the cutoff regularly and check your boiler's water level weekly

If you have a low water cutoff with a float, flush it at least once a week. This will keep the rust and gook from collecting in it and preventing it from working.

Pipe Insulation

All the piping in the basement leading to from the boiler to the radiators should be insulated. It may have had the old insulation removed in an attempt to get rid of asbestos. But these pipes should be insulated. It will eliminate or reduce the amount of water hammer (that Bang Bang bang) you may be having when the system is fired up. Be sure to use pipe insulation rated for steam piping.

Radiator pitch

Check the radiator with a level. It should be slanted toward the supply pipe. If it is not, raise the vent end with shims to get it level. Sma...

Click here to read the rest of this article from Handyman